Your gas bill talks in therms or BTU. Your electricity bill talks in kilowatt-hours. Your furnace nameplate says 80,000 BTU/h and the heat pump brochure says 7 kW. Every one of those numbers describes heat, but until they are in the same unit you cannot tell which option costs less to run.
This guide shows how BTU and kWh relate, how to turn a price per therm into a price per kWh, how efficiency changes the answer, and why a "12,000 BTU" air conditioner is not using 12,000 of anything per month. By the end you will be able to put gas and electric heating on one line and compare them honestly.
BTU, therms and kilowatt-hours
A British thermal unit (BTU) is roughly the heat needed to warm one pound of water by one degree Fahrenheit. It is small: about 1,055 joules. A kilowatt-hour (kWh) is 3.6 million joules, the energy of a 1,000-watt appliance running for an hour.
kWh = BTU ÷ 3,412.14
1 kWh = 3,412.14 BTU
Gas suppliers in North America usually bill in larger units:
| Unit | BTU | kWh |
|---|---|---|
| 1 BTU | 1 | 0.000293 |
| 1 kWh | 3,412 | 1 |
| 1 therm | 100,000 | 29.31 |
| 1 MMBtu (dekatherm) | 1,000,000 | 293.1 |
Some utilities bill in hundreds of cubic feet (CCF) of gas instead. The energy per cubic foot varies with the gas supply, so your bill should state a conversion factor to therms; use that rather than a generic figure.
BTU versus BTU per hour
A BTU is an amount of energy. A BTU per hour (BTU/h) is a rate, a power, the same kind of quantity as a watt. Equipment ratings are always rates, even when the "/h" is left off:
| Rating | Power in kW | Heat delivered in one hour at full output |
|---|---|---|
| 5,000 BTU/h window AC | 1.47 kW | 1.47 kWh |
| 12,000 BTU/h mini-split | 3.52 kW | 3.52 kWh |
| 24,000 BTU/h split system | 7.03 kW | 7.03 kWh |
| 60,000 BTU/h furnace | 17.6 kW | 17.6 kWh |
| 80,000 BTU/h furnace | 23.4 kW | 23.4 kWh |
In cooling, 12,000 BTU/h is also called one "ton" of refrigeration. Crucially, these are heating or cooling outputs, not electricity or gas inputs. An air conditioner rated 12,000 BTU/h moves 3.52 kW of heat but usually draws much less electricity than that.
Putting gas and electricity on the same scale
Here is the method, using made-up round prices so you can substitute your own tariff.
- Convert the gas price to a price per kWh. If gas costs 1.50 per therm, divide by 29.31 kWh per therm: 1.50 ÷ 29.31 ≈ 0.051 per kWh of gas energy.
- Allow for efficiency. A furnace or boiler that turns 90% of the gas energy into useful heat makes each useful kWh cost 0.051 ÷ 0.90 ≈ 0.057.
- Do the same for electricity. Resistance heaters are close to 100% efficient, so a useful kWh costs your electricity rate. Heat pumps deliver more heat than the electricity they use; the ratio is the coefficient of performance (COP). At a COP of 3, a useful kWh costs your electricity rate divided by 3.
- Compare the cost per useful kWh. Whichever is lower is cheaper to run for the same heat.
Efficiency figures come from the equipment's specification and real-world performance varies with weather and installation, so treat the result as an estimate, not a quote.
Convert BTU to kWh with our tool
The BTU to kWh Converter runs in your browser and works in both directions.
- Open the BTU to kWh Converter. The first box is labelled British thermal units (BTU).
- Enter a figure from your bill or equipment, for example
100000for one therm. The Kilowatt-hours (kWh) box shows 29.31. - Copy the result with the button beside the result line if you are building a comparison.
- Check the Formula line to see the exact factor.
- The "in other units" list shows the same energy in joules, kilojoules, calories, kilocalories and watt-hours.
- Press Swap units to go from kWh to BTU, for example to express an electricity reading in the same unit as your gas usage.
To convert a BTU/h rating to kW, enter the number as BTU: the kWh result equals the kW rating, because one hour at that rate delivers that much energy.
Other ways to do it
- Your bill. Many utilities print usage in both therms and kWh-equivalent, or state the conversion factor they used. That figure is the most accurate for your supply.
- Spreadsheet. For twelve months of bills,
=B2*29.3071converts therms to kWh and=B2/3412.14converts BTU to kWh. - Rule of thumb. 1 therm is about 29.3 kWh, and 1 kWh is about 3,400 BTU. Good enough for a first comparison.
If you are also comparing appliance power ratings in watts or horsepower, the Watts to HP Converter and HP to kW Converter cover those.
Pitfalls to watch
Mixing energy and power
A 24,000 BTU/h unit does not use 24,000 BTU a month. How much energy it uses depends on how many hours it runs and at what fraction of full output.
Forgetting standing charges
Gas and electricity tariffs often include a fixed daily or monthly charge. A cost-per-kWh comparison covers only the energy part; the fixed charges may change the overall answer if you drop one fuel entirely.
Input versus output ratings
Furnaces are often labelled with both an input BTU/h (gas burned) and an output BTU/h (heat delivered). Use output for sizing and input for fuel cost.
Using heat pump COP as a constant
Heat pump efficiency falls as the outdoor temperature drops. A single COP figure is a simplification; use the seasonal figure from the manufacturer where available.
Frequently asked questions
How many kWh are in a therm?
One therm is 100,000 BTU, which is 29.31 kWh.
How many BTU are in 1 kWh?
One kilowatt-hour equals 3,412.14 BTU.
What does a 12,000 BTU air conditioner mean in kW?
It means 12,000 BTU per hour of cooling, which is 3.52 kW of cooling output. The electricity it draws is usually lower, depending on its efficiency.
Is gas or electric heating cheaper?
It depends on your local gas and electricity prices and on equipment efficiency. Convert both to a cost per useful kWh using the steps above to compare them.
What is the difference between BTU and BTU/h?
BTU is an amount of energy; BTU/h is a rate of energy flow, like watts. 1 BTU/h is about 0.293 W.